System Overview
System Purpose The FS10 is a dedicated control and monitoring system for fixed aerosol fire suppression systems in non-IMO marine applications. You find the FS10 system in two variants, a normal bracket mount unit and a flush mount unit, the function is the sa...
Introduction
Purpose of the Manual This manual provides operational guidance for the FS10 system. It describes normal operation, fire response, manual and automatic activation, fault indications, and operator-level maintenance procedures. Installation, service, cabling, an...
Safety Information
Safety Definitions WARNING – Hazard that may cause serious injury or death.CAUTION – Risk of equipment damage.NOTICE – Operationally important information. General Safety Warnings WARNING – Automatic Fire Suppression The system may activate automatically. Do ...
Controls and Indicators
Front Panel Overview Indicators and buttons 1. Activation buttons For manual activation in case of fire hold both buttons for at least 3 seconds to activate the aerosol generators. The aerosol generators will be activated after an activation delay set during ...
Normal Operation
Power-On Behaviour System OK LED must turn green. Fault LED must be off. No audible fault indications. Monitoring Mode The FS10 continuously monitoring aerosols, power, switches, and internal circuits. FS10 also monitoring external detectors, fire alar...
Fire Alarm Operation
Fire Detection Fire LED (red). Buzzer active. Fire relay active. Automatic Activation Sequence (if enabled) Fire detected. Activation delay begins. Activation LED blinks. Warning devices activate. Aerosol discharge occurs after delay. Manua...
Abnormal & Emergency Conditions
General Fault Behaviour Fault LED (yellow). Buzzer intermittent. Fault relay active. Common Faults See 9, TROUBLESHOOTING
Operator Maintenance
Permitted Tasks Visual inspection. Indicator check. Alarm acknowledgement. Prohibited Tasks Opening enclosure. Wiring changes. Firmware changes. Aerosol connection. Routine Inspection Make sure at least one LED is lid. Check for No Fault ...
Troubleshooting
Detecting faults Press Button Mute / Reset / Lamp test for > 3 seconds. This will flash one of the LEDs. Recognize the type of fault according to below: Flashing LED Numbers of Flash . Action No LEDs No power Check supply, technician Power Supp...
Document References
The FS10 system is supported by the following documents: Document Description FS10 Service Manual Installation, wiring, commissioning, diagnostics, fault scenarios. FS10 Datasheet Technical specifications for power, detectors, aerosols, relays. FS10...
Appendix
Appendix A FS10 Main Unit, Activating the aerosol generators Press both Activation buttons (1) for at least 3 seconds. The ventilation in the protected area is turned off. The activation delay time elapses. (0s-120s, set during commissioning). During thi...